Paper Titles in Periodical
International Letters of Chemistry, Physics and Astronomy
Volume 64
Subscribe

Subscribe to our Newsletter and get informed about new publication regulary and special discounts for subscribers!

ILCPA > Volume 64 > Simulate and Study the Effect of Compton...
< Back to Volume

Simulate and Study the Effect of Compton Scattering Angle on the Radiography Inspection

Full Text PDF

Abstract:

Radiography inspection have been used in this work to detects and image the corrosion in the outside surface of the pipe. Gamma ray with 0.662 MeV from 127Cs source have been chosen for this inspection while NaI(Tl) detector is use to detect and collect the scatter photons with radius 6cm. A simulation follow the history of photon by using Fortran Language and concerned on the effect of Compton scattering angle on the count rate of scatter photons and on the quality of the image. The Compton scattering angles that study are in the range from (90°-100°) to (170°-180°) with step 10°. The results show that the greater count rate of scattered photons is improved in the angle range (90°-100°). Therefore, the count rate decreases with increasing the angle range especially within the range (170°-180°) which has a minimum count rate and affect on the image resolution, then it could not distinguish between the corrosion and non-corrosion region.

Info:

Periodical:
International Letters of Chemistry, Physics and Astronomy (Volume 64)
Pages:
11-18
Citation:
I. T. Al-Alawy et al., "Simulate and Study the Effect of Compton Scattering Angle on the Radiography Inspection", International Letters of Chemistry, Physics and Astronomy, Vol. 64, pp. 11-18, 2016
Online since:
February 2016
Export:
Distribution:
References:

[1] IAEA, Guid Book for the Fabrication of Non-Destructive Testing (NDT) Test Specimens, published by International Atomic Energy Agency IAEA, Vienna, (2001).

[2] R. A. Quinn and C. C. Sigl, Radiography in Modern Industry, 4th edition, © Eastman Kodak Company, Rochester, New York, (1980). http: /www. kodak. com/eknec/documents/87/0900688a802b3c87/Radiography-in-Modern-Industry. pdf.

[3] G. Harding, Inelastic Photon Scattering: Effects and Applications in Biomedical Science and Industry, Radiation Physics and Chemistry, 50 (1), (1997), 91–111.

[4] Kimiya Aoki and Yasuo Suga, Application of Artificial Neural Network to Discrimination of Defect Type in Automatic Radiographic Testing of Welds, ISIJ International, 39(10), (1999), 1081-1087.

[5] N. Shengli, Z. Jun and H. Liuxing, EGS4 Simulation of Compton Scattering for Nondestructive Testing, Proceedings of the Second International Workshop on EGS, 8. -12. August 2000, Tsukuba, Japan KEK Proceedings 200-20, (2000), 216-223.

[6] Uwe Zscherpel, Uwe Ewert, Bam, Silvia Infanzon, Aendur, Nasser Rastkhan, P. R. Vaidya, Isaac Einav and Sinasi Ekinci, Radiographic Evaluation of Corrosion and Deposits in Pipelines: Results of an IAEA Co-ordinated Research Programme, ECNDT Mo. 2. 4. 1, (2006).

[7] K. Banerjee and W.L. Dunn, On X-ray Back-Scattering to Detect Hidden Cracks in Multi-Layer Structures, Applied Radiation and Isotopes, 65(2), February (2007), 176-182.

[8] Edson Vasques Moreiraa, Heleno Ribeiro Simõesa, José Maurício Barbosa Rabellob, José Rubens de Camargob and Marcelo dos Santos Pereira, Digital Radiography for the Inspection of Weld Seams of Pipelines – Better Sensitivity, Taylor and Francis Online, Welding International, 24(4), (2010).

[9] Alexander Boateng, K.A. Danso and C.P.K. Dagadu, Non-Destructive Evaluation of Corrosion on Insulated Pipe Using Tangential Radiographic Technique, International Journal of Scientific and Technology Research, www. ijstr. org, 2(6), (2013), 7-13.

[10] S. Kolkoori, N. Wrobel, K. Osterloh, U. Zscherpel and U. Ewert, Novel X-ray Backscatter Technique for Detection of Dangerous Materials: Application to Aviation and Port Security, Journal of Instrumentation, 8, September (2013), 09017.

[11] M. Willcox and G. Downes, A brief Description of NDT Techniques, Insight NDT Equipment Limited, 2003, (2000). www. InsightNDT. com.

[12] J. Brett. Ingold and AMMTIAC Rome NY, "Selecting a Nondestructive Testing Method, Part VI: Thermal/Infrared Inspection Techniques-Thermography", techsolutions08, , The AMMTIAC Quarterly, 3(2), (2006), 9-12. ‎Related article [7] Hardy, G., “Thermal Inspection,” ASM Metals Handbook, Ninth Edition, Nondestructive Evaluation and Quality Control, ASM International, 17, 396-404. http://ammtiac.alionscience.com/quartely

[13] Radiography Testing-NDT InspectionTWI Ltd, The Welding Institute TWI Ltd, Grant Park, Great Abington, Cambridge CB21 6AL, United Kingdom, (2015). www. twi-global. com/capabilities/.. testing/ndt.. /radiography-testing.

[14] Niazi Ali Haj Omer Mohammed, Estimation of Radiation Dose Received by the Radiation Workers during Radiographic Testing, M. Sc. thesis in Radiation Protection and Environment, Atomic Energy Council, Sudan Academy of Sciences, August (2013).

[15] Corrosion and Erosion: Inspection Solutions for Detection, Sizing and Monitoring, General Electric Company GE Inspection Technologies, GEIT-10017EN (06/10), (2010). www. geit. com.

[16] E. Bardal and J. M. Durgli, Corrosion Detection and Diagnosis, Materials Science and Technology, in Encyclopedia of Life Support System, Developed under the Auspices of the UNESCO, Eolss Publishers, Oxford, UK, (2004).

[17] J. H. Hubbell and S. M. Seltzer, Tables of X–Ray Mass Attenuation Coefficients and Mass Energy–Absorption Coefficients from 1 keV to 20 MeV for Elements Z= 1 to 92 and 48 Additional Substances of Dosimetric Interest, National Institute of Standard and Technology (NIST), Physical Measurement Laboratory, 19, (2015).

[18] A. J. Ball, Measuring Physical Properties at the Surface of a Comet Nucleus, Ph.D. Thesis. Units for Space Science and Astrophysics, University of Kent, Canterbury, UK, December (1997).

[19] A. J. Ball, C. J. Solomon and J. C. Zarnecki, The Response of Gamma Backscatter Density Gauges to Spatial Inhomogensity–an Extension of the Single Scattering Model, Nuclear Instruments and Methods in Physics Research B, 140, (1998).